Product Name: | Waterproof MPO Breakout Cable | Connector: | MPO To LC |
---|---|---|---|
Key Words: | MPO Breakout Cable | Application: | Outdoor Use |
Highlight: | Waterproof MPO Breakout Cable,MPO Breakout Cable,MPO To LC |
MPO Breakout Cable facilitate rapid deployment of high density backbone cabling in data centers and other high optical environment, reducing network in stallation or reconfiguration time and cost.
MPO are used to interconnect cassettes, panels, or fan outs, it offered in fiber typs in standard 8 , 12 ,24 cores
versions using a compact and rugged microcables structre. The compact cable optimize cableway use and improve airflow.
These MPO cable are build with the highest quality components , Low loss elite versions are offered, featuring low insertion low for demanding high speed networks where power budgets are critical.
Application
1. Multi-purpose Outdoor.
2.For connection between distribution box and RRH. 3.Deployment in Remote Radio Head cell tower applications.
1.Cost effective solution for in house termination. 2.Low insertion loss and added loss.
3. Height of attenuation.
4. Water proof, dust proof and corrosion resistant
5.The material in the jumpel cable are all-weather and UV-resistant. 6.IP68 water and dust protection.
6.Mechanical performance: IEC 61754-7 standard. 8.RoHS and REACH materials compliant.
Type | Reference | Note | |
MPO |
IEC 61754-7 |
Single mode |
APC: Black connectors APC: Black connectors |
Multimode | PC: Black Connectors | ||
MTP |
IEC 61754-7 |
Single mode |
APC: Black connectors APC: Black connectors |
Multimode | PC: Black Connectors |
Dimensional Diagrams
1. Mini IP MPO Outdoor Cable Assemblies
Jumper tolerance requirement | |
Overall length (L) (M) | length of tolerance(CM) |
0<L≤20 | +10/-0 |
20<L≤40 | +15/-0 |
L>40 | +0.5%L/-0 |
Cable Structure
Cable Parameters
Cable Count |
Out sheath Diameter (MM) |
Weight (KG) |
Minimum allowable Tensile Strength (N) |
minimum allowable Crush Load (N/100mm) |
Minimum Bending Radius (MM) |
Storage temperature (℃) |
|||
short term | long term | short term | long term | short term | long term | ||||
8/12/24 | 5.0±0.3 | 32 | 500 | 250 | 750 | 300 | 20D | 10D | -20 ~~ +70 |
Cable Parameters
Cable Count |
Out sheath Diameter (MM) |
Weight (KG) |
Minimum allowable Tensile Strength (N) |
minimum allowable Crush Load (N/100mm) |
Minimum Bending Radius (MM) |
Storage temperature (℃) |
|||
short term | long term | short term | long term | short term | long term | ||||
8/12/24 | 5.0±0.3 | 32 | 500 | 250 | 750 | 300 | 20D | 10D | -20 ~~ +70 |